Snap-Stat, Snap Action
Plugstat Bimetallic Strip
Rod & Tube
X Series
W Series
AB Series


 

THERMAL SWITCHES: Rod & Tube

Type X1 and X2




Rod & Tube Thermal Switches
0°F - 1850°F calibration range

  • SPST, two terminal
  • All stainless steel
  • Meets MIL environments
  • Torque free mounting
  • Factory calibrated and sealed
  • Optional field adjustment feature available
See RTCA DO-160C data summary

MIL STD 810 X1 & X2
High Temperature Meth. 501.2 Proc.I
Soak Temp. 700°F
  Vibration & Shock Test data can be made available to meet customer requirements
Low Temperature Meth. 502.2 Proc.I
Soak Temp. -70°F
  Moisture Resist.  MIL S 24236
P. 4.7.13 10 day
 
Fungus Meth. 508.3 Proc.I

X1 X2     X1 X2
Calibration Temp. Max 850°F 1850°F   Safe Momentary
Undershoot
Probe Overshoot
Head

-65°F
1000°F
800°F

-65°F
2000°F
800°F
Calibration Temp. Min 0°F 100°F   Voltage 115AC/28DC 115AC/28DC
Calibration Tolerance ±5°F ±10°F   Current
Resistive
Inductive

1 amp
_amp

1 amp
_amp
Repeatability ±3°F ±3°F   Weight 1.5 oz 2 oz
Differential (normal) 3°F 5°F   Response time per
MIL S 24236, P4.7.5.1
5 sec. Max 5 sec. Max
Proof Pressure (probe only) P.S.I.G. 3000 3000

  • Contact action available to close on rising or close on falling temperature.
  • Close tolerance set points are available at a premium charge.
  • Values shown are optimum. Consult our Sales Engineering Dept. for specific application information.
  • Electrical connections:
    a. Two wire electrically isolated from ground.
    b. Terminals provided
  • Lockwire hole: .067" Max.