| M1
& M2 |
|
CPI
Bimetal switches that meet or exceed environmental requirements
of MIL STD 810 as follows: |
| Calibration
Temp. Max |
650°F |
High
Temperature |
Meth.
501.2 Proc.I
Soak Temp. 700°F |
| Calibration
Temp. Min |
0°F |
Low
Temperature |
Meth.
502.2 Proc.I
Soak Temp. -70°F |
Calibration
Tolerance
(above 440°F, ±7°F) |
±5°F |
Humidity |
Meth.
507.2 Proc.I |
| Repeatability |
±3°F |
Salt
Fog |
Meth.
509.2 Proc.I |
| Differential
(norm) |
0¹-5°F |
Fungus |
Meth.
508.3 Proc.I |
| Proof
Pressure |
4000
psi |
Dust
& Sand |
Meth.
510.2
Proc.I Dust
Proc.II Sand |
Safe
Momentary
Undershoot
Overshoot |
-70°F
800°F |
Vibration |
Test
data can be made available to meet customer requirements |
| Voltage |
115AC/28DC |
Shock |
Meth.
514.3 Proc.I
Fractional shock |
Current
Resistive
Inductive |
2 amps
_Amp |
Altitude
Temp |
Meth.
504.1 Proc.I |
Life
Mechanical
Full Rated Load |
3,000,000 cyc
10,000 cyc |
Moisture
Resist. |
MIL
S 24236
P. 4.7.13 10 day |
| Weight |
M1
1.1 oz
M2 1.5 oz |
Response
time per MIL
S 24236, P4.7.5.1 |
25
to 45 sec. |